| Problem | Error Code(s) | Probable Cause | Solution | Notes |
| Not heating / temp. dropping (displaying room temperature) | A05 | Hi limit tripped | Press reset under heater | • Low / dirty oil will cause the hi limit to trip. • Dirty plugs can disrupt voltage to the heater or cause the hi limit to trip. |
| Dirty / damaged heater plug connection | Clean / replace plugs | |||
| Dirty / low oil | Filter / change oil | |||
| Temperature fluctuation (temp. fluctuation of 5-10°F is normal) |
A07 A08 PRB |
Low oil level | Change / add oil. | • Dirty / greasy plug connections can cause the temp. to fluctuate or give false readings. • Cleaning the plug connection on a weekly basis with a q-tip and acetone will prevent poor connections. |
| Dirty / damaged probe plug connection | Clean / replace plugs | |||
| Overloading basket | Be sure not to cook more than your AutoFry models capacity | |||
| Not allowing proper recovery time | Allow temp. to recover before entering next batch | |||
| Basket not dumping product |
A04 | Basket out of adjustment | Adjust basket rod | • Go to our youtube page to watch basket adjustment instructional video. • The basket should sit above the oil pot at a slight angle (2.5-3” above). If the basket is out of position, damage to the gear box will result. |
| Product sticking to basket | Teflon worn, replace basket | |||
| Basket cam loose | Check / tighten basket cam | |||
| Blown secondary fuse | Check / replace fuse | |||
| Damaged motor / gear box | Replace motor assembly | |||
| Product going underneath basket | A04 | Basket out of adjustment | Adjust basket rod | • Go to our youtube page to watch basket adjustment instructional video. • The basket should sit above the oil pot at a slight angle (2.5-3” above). If the basket is out of position, damage to the gear box will result. |
| Product entered before display shows ready | Always wait until display shows ready before opening entry chute | |||
| Basket falling out of bracket | A04 | Basket out of adjustment | Adjust basket rod | • Go to our youtube page to watch basket adjustment instructional video. • The basket should sit above the oil pot at a slight angle (2.5-3” above). If the basket is out of position, damage to the gear box will result. |
| Basket not fully seated in receiver clip | ||||
| Opening entry chute before the unit displays ready | Always wait until display shows ready before opening entry chute | |||
| Outside of AutoFry is hot to touch |
SFT | Charcoal filter still in plastic | Remove charcoal filter plastic | • Charcoal filter must be changed at least every three months to maintain proper ventilation. Sooner with high volume locations. |
| Charcoal filter clogged | Replace charcoal filter | |||
| Exhaust fan blocked or not running | Clean / replace fan | |||
| Strong odor from AutoFry |
N/A | Charcoal filter clogged | Replace charcoal filter | • Cooking oil is the biggest factor in regard to odor. Some oils are much more fragrant than others. • Charcoal filter must be changed at least every three months to maintain proper ventilation. Sooner with high volume locations. |
| Exhaust fan blocked or not running | Clean / replace fan | |||
| Dirty oil | Filter / change oil | |||
| Excess condensation on exterior / interior |
SFT | Charcoal filter still in plastic | Remove charcoal filter plastic | • Fresh products with excess moisture will produce excess condensation. • Charcoal filter must be changed at least every three months to maintain proper ventilation. Sooner with high volume locations. |
| Charcoal filter clogged | Replace charcoal filter | |||
| Exhaust fan blocked / not running | Clean / replace fan | |||
| Excessive product moisture | Reduce ice / moisture in product | |||
| Door gasket worn | Replace gasket | |||
| Excess oil underneath oil pot |
N/A | Drain valve open / blocked | Close / clean / replace valve | • Dirty oil is prone to surge boiling. • Products with excessive ice / moisture can cause oil to boil over. • Clean the interior regularly. |
| High oil level | Lower oil level | |||
| Excessive product moisture | Reduce ice / moisture in product | |||
| Dirty oil | Filter / change oil | |||
| Overloading basket | Be sure not to cook more than your AutoFry models capacity | |||
| Oil pot leaking | Replace oil pot | |||
| Display blue | N/A | Excess moisture on display board | Remove display and set aside to dry | • Typically caused from poor ventilation. • Charcoal filter must be changed at least every three months to maintain proper ventilation. Sooner with high volume locations. |
| Replace charcoal filter | ||||
| Check / replace silicone seal around display compartment | ||||
| Poor ribbon cable connection | Replace Display | |||
| AutoFry won’t turn on | N/A | Tripped breaker | Reset breaker | • There are four fuses in the back of the AutoFry. Check all four. If the problem continues contact technical support. |
| Blown fuses | Check / replace fuses | |||
| Trace voltage to circuit board | ||||
| AutoFry shut off in the middle of cook cycle | N/A | Basket jammed | Remove basket, turn on and cycle without basket | • If the basket comes out of its normal position and jams, it will likely over Amp, causing the secondary fuses to blow. |
| Motor / gearbox jammed | Check / replace motor assembly | |||
| Blown fuses | Check / replace fuses | |||
| Don’t hear fan running | SFT | Charcoal filter clogged | Replace charcoal filter | • The exhaust fan should run anytime the oil is hot and/or trying to heat. • The fan will continue to run until the oil cools below 192°F. |
| Exhaust fan blocked / not running | Clean / replace fan | |||
| Safety Switch – Front Door | SFT | Front door open | Close door, turn AutoFry off then on again. | • All switches are normally open. Switch should be closed for normal operation. Check switch for continuity. |
| Door gasket worn | Check / replace door gasket | |||
| Switch gummed with grease | Clean Switch of grease | |||
| Switch failed | Check / replace Switch | |||
| Safety Switch – Charcoal Filter | SFT | Charcoal filter not installed | Install charcoal filter | • All switches are normally open. Switch should be closed for normal operation. Check switch for continuity. |
| Charcoal filter dented, not making contact | Check / replace charcoal filter | |||
| Filter cover plate not tight | Tighten filter cover plate | |||
| Switch gummed with grease | Clean switch of grease | |||
| Switch failed | Check / replace switch | |||
| Safety Switch – Mesh Filter | SFT | Mesh filter not installed | Install mesh filter | • All switches are normally open. Switch should be closed for normal operation. Check switch for continuity. |
| Mesh Filter dented, Not making contact | Check / replace mesh filter | |||
| Filter cover plate not tight | Tighten filter cover plate | |||
| Switch gummed with grease | Clean switch of grease | |||
| Switch failed | Check / replace switch | |||
| Safety Switch – Grease Baffle | SFT | Grease baffle not installed | Install grease baffle | • All switches are normally open. Switch should be closed for normal operation. Check switch for continuity |
| Grease baffle dented, not making contact | Check / replace grease baffle | |||
| Filter cover plate not tight | Tighten filter cover plate | |||
| Switch gummed with grease | Clean switch of grease | |||
| Switch failed | Check / replace switch | |||
| Safety Switch – Filter Cover Plate | SFT | Filter cover plate on backwards | Install filter cover plate correctly | • All switches are normally open. Switch should be closed for normal operation. Check switch for continuity |
| Filter cover plate not tight | Tighten filter cover plate | |||
| Switch gummed with grease | Clean switch of grease | |||
| Switch failed | Check / replace switch | |||
| Safety Switch – Fire System | SFT | Fire System discharged | Call fire equipment company for service | • Fire suppression system must be serviced every six months by a licensed fire equipment company. |
| Fire System low pressure | ||||
| Switch failed | ||||
| Safety Switch – Fire Damper | SFT | Fire damper not installed | Install fire damper | • All switches are normally open. Switch should be closed for normal operation. Check switch for continuity |
| Fire damper dented, Not making contact | Check / replace Fire damper | |||
| Switch gummed with grease | Clean Switch of grease | |||
| Switch has failed | Check / replace Switch | |||
| Basket hits against side wall | N/A | This is normal | This is normal | The basket will hit against the side wall twice to ensure all product has dumped. |